Column chromatography in chemistry is a method used to purify individual chemical compounds from mixtures of compounds. It is often used for preparative applications on scales from micrograms up to kilograms.
The classical preparative chromatography column is a glass tube with a diameter from 5 to 50 mm and a height of 50 cm to 1 m with a tap at the bottom. A slurry is prepared of the eluent with the stationary phase powder and then carefully poured into the column. Care must be taken to avoid air bubbles. A solution of the organic material is pipetted on top of the stationary phase. This layer is usually topped with a small layer of sand or with cotton or glass wool to protect the shape of the organic layer from the velocity of newly added eluant. Eluant is slowly passe4d through the column to advance the organic material. often a spherical eluant reservoir or an eluant filled and stoppered separating funnel is put on top of the column
the individual component are retained by the stationary phase differently and separate from each other while they are running at different speeds through the column with the eluant.At the end of the column the elute one at a time.During the entire chromatographic process the eluant is collected in a series of fractions.The composition of the eluant flow can be monitored and each fraction is analyzed for dissolved components e-g by analytical chromatography UV absorption or fluorescence. Coloured compounds can be seen through the glass wall as moving bands.
Stationary phase (adsorbent)
The stationary phase or adsorbent in column chromatography is a solid. The most common stationary phase for column chromatography is silica gel followed by alumina . Cellulose powder has often been used in the past. Also possible are ion exchange chromatography,reversed phase chromatography (RP), affinity chromatography or expanded bed adsorption (EBA). The stationary phases are usually finely ground powders or gels and/or are microporous for an increased surface, though in EBA a fluidized bed is used.
The mobile phase or is eluent either a pure solvent or a mixture of different solvents. It is chosen so that the rention factor value of the compound of interest is roughly around 0.75 in order to minimize the time and the amount of eluent to run the chromatography. The eluent has also been chosen so that the different compounds can be separated effectively. The eluent is optimized in small scale pretests, often using thin layer chromatography (TLC) with the same stationary phase.
A faster flow rate of the eluent minimizes the time required to run a column and thereby minimizes diffusion, resulting in a better separation,see van Deemter's equation. . A simple laboratory column runs by gravity flow. The flow rate of such a column can be increased by extending the fresh eluent filled column above the top of the stationary phase or decreased by the tap controls. Better flow rates can be achieved by using a pump or by using compressed gas (e.g. air,nitrogen, or argon) to push the solvent through the column (flash column chromatography
A spreadsheet that assists in the successful development of flash columns has been developed. The spreadsheet estimates the retention volume and band volume of analytes, the fraction numbers expected to contain each analyte, and the resolution between adjacent peaks. This information allows users to select optimal parameters for preparative-scale separations before the flash column itself is attempted.